Two 0.100" (2.54mm) headers are provided for measurement with a differential probe. One (JP7) is directly across the resistor, and the other (JP6) is on the top right side of the PCB. JP6 is designed to be used with a NewAE Technology Inc. differential probe (which requires a separate power supply for this differential probe).
Examples of resistors used are the following:
{| class="wikitable"
!Value
!Manufacture
!Part Number
!Digikey P/N
|-
|500mOhm
|Stackpole
|CSR1206FKR500
|CSR1206FKR500CT-ND
|-
|250mOhm
|Stackpole
|CSR1206FKR250
|CSR1206FKR250CT-ND
|-
|100mOhm
|Samsung
|RUW3216FR100CS
|1276-6187-1-ND
|-
|50mOhm
|Vishay
|WSLP1206R0500FEA
|WSLP-.05CT-ND
|}
=== VCC-INT Decoupling Capacitors ===