20:23, 17 September 2017 <h2> Setting up the Hardware </h2>
This tutorial uses the [[CW1200_ChipWhisperer-Pro]] hardware.
# Remove the ChipWhisperer-Pro main capture hardware, UFO Board, and SMA cable from the ChipWhisperer-Pro case.
# Attached the UFO board to the ChipWhisperer-Pro with the 20-pin cable, and connect the '''VOUT''' SMA connector to the '''MEASURE''' input.
# Power up the ChipWhisperer-Pro with the 5V DC power adapter, and connect the USB cable to the computer.
# If this the first time powering up, you will need to install the drivers (see [[CW1200_ChipWhisperer-Pro]]).
[[File:cwpro_setup.jpg]]
Note if you have modified the UFO board the jumpers may no longer be at default locations. The jumper settings required are:
[[File:cwpro_ufo_setup.jpg]]
# XMEGA Target board mounted
# J3 routes HS2/OUT to CLKIN
# J1 set to "J5-VREF" (right two pins shorted)
# J14 set to "FILT" (left two pins shorted)
# "3.3V SRC" switch set to "J1/CW"
{{:Setting up Software for B1}}